Reducing the Post-Pump Syndrome by Using Heparin-Coated Circuits, Steroids, or Aprotinin
83
Citations
0
References
1999
Year
The results show a similar reduction of the inflammatory cytokine release (IL-6 and IL-8 as markers) using early steroid application and aprotinin in high dosage. Heparin coating reduces IL-6 and increases IL-10 release, whereas IL-8 is not affected. Further studies should investigate the effects of a combined application for reducing inflammatory cytokine release and the post-pump syndrome.