An Instrument for Retrieval of Intravascular Foreign Bodies

Klaus Ranniger

Radiology · 1968 · 19 citations · 6 references

Concepts

Abstract

Increasing use of indwelling venous catheters and percutaneous venous catheterization has led to a rather uncommon complication resulting from the loss of a catheter or guide wire into the venous system. The displaced foreign body may become lodged in any portion of the venous system, but most frequently is located in the right atrium or right ventricle. If the foreign body is radiopaque, it can easily be located by fluoroscopy. If it is not radiopaque, a contrast material injection will occasionally produce a negative image of the dislodged material. Since the displaced material might produce cardiac arrhythmias, thrombi leading to pulmonary emboli, or perforate a vessel, the foreign body is usually removed. In general, the removal is by surgical intervention, which may be major if the heart has to be opened, and tedious if the lost material is not located at once. Several cases have been described recently in which the catheter was successfully removed transvascularly by instruments which were not originally designed for such use (8, 10, 12). Bronchoscopy forceps, specially shaped catheters, or looped guide wires have been employed to remove a foreign body from the heart or great vessels and maneuver it into a peripheral vein so that it could be removed by a cut-down. We have designed a simple instrument which can be introduced easily into the venous system percutaneously through a gray Ödman catheter. It consists of a PE 205 spiral guide wire without an inner core. Three small steel wires each 1 cm long have been soldered to the end of the guide wire. Each of the wires has a small loop at its distal end. A nylon line is threaded through the three loops and then through the lumen of the guide wire. By pulling the nylon line at the proximal guide wire end, the three steel prongs are approximated, while release of the line allows the prongs to spread apart. This procedure of opening and closing the prongs can be done intravascularly under fluoroscopic control. This instrument was evaluated in 10 dogs with fragments of metallic guide wires lodged in the right atrium and right ventricle. In all 10 animals we were able to grasp the guide wire and retract it from the heart into the femoral vein where it could be removed without a surgical procedure. There were no complications other than local hematomas at the puncture site. Discussion Transvascular retrieval of a foreign body lodged in the venous system should be attempted prior to surgical removal. Although several makeshift instruments have been used for transvascular retrieval, most of them can be introduced only after a venous cut-down and, furthermore, the foreign body retracted from the heart must be removed surgically from the peripheral vein. This paper describes a simple instrument for transvascular retrieval which has proved usable in all 10 of the test animals.

References

6