Radiology · 1994 · 70 citations · 0 references
Contrast material volume and injection rate have interdependent effects on liver enhancement and potentially tumor conspicuity. Higher rates compensate partially for lower volume, but enhancement is still reduced. The optimal window of time for imaging after injection varies with injection technique.