The Journal of Physical Chemistry C · 2007 · 177 citations · 60 references
Natural SciencesChemistryMaterials ScienceFunctional MaterialsInorganic ChemistrySurface ScienceLigand BindingRedox-active MaterialsSensor MaterialsSupramolecular MaterialsSurface Functionalization Of NanomaterialsSurface ReactivityChemical Sensor MaterialsMesoporous Hybrid MaterialsMesoporous MaterialsMesoporous NanomaterialsOxygen Monitoring SensorsOxygen SensingOxygen SensorsRuthenium-catalyzed Coupling
Novel oxygen sensing materials consisting of the [Ru(dpp) 2 Phen] 2+ (dpp = 4, 7-diphenyl-1,10-phenanthroline, Phen = 1,10-phenanthroline) portion covalently grafted to the ordered functionalized mesoporous SBA-15 and MCM-41 backbones are prepared by co-condensation of tetraethoxysilane (TEOS) and the functionalized Ru(II) complex [Ru(dpp) 2 Phen-Si] 2+ (Phen-Si = 2-[4‘-{3-(Triethoxysilyl)propyl}phenyl]imidazo [4,5-f]-1,10-phenanthroline) in the presence of Pluronic P123 or cetyltrimethylammoniumbromide (CTAB) surfactant as template, respectively. 1,10-Phenanthroline covalently grafted to 3-(triethoxysilyl)propyl isocyanate is used not only as the precursors but also as the second ligand of the Ru(dpp) 2 Cl 2 ·2H 2 O complex to prepare the functionalized mesoporous materials for oxygen sensors. For comparative purposes, two different synthesis procedures, including the one-pot synthesis and the postsynthetic treatment methods, are used to prepare the covalently grafted samples. Furthermore, the oxygen sensing materials in which [Ru(dpp) 2 Phen] 2+ is conventionally physically incorporated into the matrix are also prepared. The derivative mesoporous oxygen sensing materials are characterized by Fourier transform infrared (FT-IR), scanning electron microscopy (SEM), small-angle X-ray diffraction, luminescence intensity quenching Stern−Volmer plots, nitrogen adsorption/desorption, elemental analysis, and excited-state decay analysis. The functionalized mesoporous sensing materials appear to be highly sensitive to the O 2 concentration in N 2 . In addition, these mesoporous sensing materials exhibit short response times and can be restored within seconds. The oxygen quenching result shows that the homogeneity and the sensitivity of the covalently assembled samples are superior to those of the physically incorporated ones. Furthermore, a greatly minimized leaching effect of the sensing molecules could be observed in the covalently grafted systems. In addition, the Ru(II)Phen-MCM-41 oxygen sensing materials show an overall increase in luminescent lifetime compared with the Ru(II)Phen-SBA-15 oxygen sensing materials, which is explained in detail by the difference of Ru(II) content and pore structure between the two kinds of mesoporous oxygen sensing materials.
60
Ordered mesoporous molecular sieves synthesized by a liquid-crystal template mechanism
Charles T. Kresge, M. E. Leonowicz, Wiesław J. Roth et al. · Nature · 1992 · 16.1K citations
Triblock Copolymer Syntheses of Mesoporous Silica with Periodic 50 to 300 Angstrom Pores
Dongyuan Zhao, Jianglin Feng, Qisheng Huo et al. · Science · 1998 · 11.6K citations
Dongyuan Zhao, Qisheng Huo, Jianglin Feng et al. · Journal of the American Chemical Society · 1998 · 6.6K citations