Prosthetics and Orthotics International · 2013 · 27 citations · 6 references
MedicineOrthopaedic SurgeryRehabilitation MedicineAmputee RehabilitationOrthopedic RehabilitationOrthopedicsGait AnalysisGait AssessmentGait EvaluationLower Extremity RehabilitationLower Limb RehabilitationProsthetic FittingAmputee LocomotionDescent PerformanceInterrater ReliabilityKnee Function AssessmentLower-limb Prosthesis AssessmentProsthetic Outcome AssessmentTransfemoral Prosthetic Gait
Background: Transfemoral amputees have decreased ability to descend ramps and hills. The Hill Assessment Index quantifies transfemoral amputee ramp performance, but interrater reliability has not been assessed. Objectives: To determine whether C-Leg use improves hill descent gait and evaluate the Hill Assessment Index’s interrater reliability. Methods: Twenty-one transfemoral amputees descended a ramp while timed and video recorded, using their nonmicroprocessor prosthetic knee. Subjects were fitted and accommodated with a C-Leg and retested. Test times were compared, and ramp performances were independently reviewed using the Hill Assessment Index by two raters. Hill Assessment Index scores were compared between knee conditions within raters for performance and between raters to assess the Hill Assessment Index’s interrater reliability. Results: Mean Hill Assessment Index scores were greater for C-Leg compared to nonmicroprocessor prosthetic knee for both raters. C-Leg resulted in faster ramp descent. Strong correlations resulted between raters on Hill Assessment Index scores for nonmicroprocessor prosthetic knee (intraclass correlation coefficient = 0.97) and C-Leg (intraclass correlation coefficient = 0.99). Conclusions: C-Leg improves Hill Assessment Index ramp descent performance and time. In descent quality, C-Leg offers the possibility of eliminating assistive device use and/or improving step length in the absence of an assistive device. C-Leg resulted in 23% gait speed increase during ramp descent. The Hill Assessment Index had very good interrater reliability but should be assessed for intrarater reliability, minimal detectable change, and validity. Clinical relevance Transfemoral amputees have difficulty ambulating on ramps. While the C-Leg has been shown to improve ramp descent, this has not been confirmed, and the Hill Assessment Index has not been studied for reliability. This study confirms that the C-Leg improves ramp descent performance and the Hill Assessment Index’s interrater reliability.
6
Brian J. Hafner, Laura L. Willingham, Noelle C. Buell et al. · Archives of Physical Medicine and Rehabilitation · 2007 · 314 citations
Reliability of Observational Kinematic Gait Analysis
David E. Krebs, Joan E. Edelstein, Sidney Fishman · Physical Therapy · 1985 · 303 citations
Jason T. Kahle · The Journal of Rehabilitation Research and Development · 2008 · 221 citations
Uphill and downhill walking in unilateral lower limb amputees
Aline H. Vrieling, Helco G. van Keeken, Tanneke Schoppen et al. · Gait & Posture · 2008 · 135 citations · Full text