Dual-pressure Air Receiver Cycle for Direct Storage Charging

Lukas Heller, Paul Gauché

Energy Procedia · 2014 · 11 citations · 9 references

DOIFull text

Open access

Concepts

Abstract

Combined cycle solar thermal power plants are expected to bring an efficiency increase as compared to state-of-the-art cycles. A passive sensible heat storage system in the low pressure part is expected to enable dispatchability of such a plant. However, the amount of energy available for the bottoming cycle is limited to the exhaust energy of the gas turbine. This is not sufficient if high solar shares and the generation of large amounts of electricity throughout the day and night are aspired. SUNDISC, a cycle with a dual-pressure receiver system, is proposed to address this limitation. Energy dumping through defocusing can be replaced by refocusing onto the low-pressure receiver system, which directly charges the storage system and, therefore, allows more energy to be harnessed during daytime. This potentially enables the bottoming cycle to be of comparable rating to the top cycle while still running throughout the night. A comparison of a non-optimized SUNDISC cycle and a layout without the low-pressure receiver system showed a 10% larger annual power generation of the former. Further improvements in solar share, power generation and dispatchability are expected for systems that are optimized for the respective requirements. Additional advantages in the areas of heliostat field optics and operational consistency have yet to be quantified.

References

9