Case Reports in Ophthalmology · 2010 · 13 citations · 10 references
MedicineOphthalmologySurgeryMyopia ManagementOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionCataract SurgeryMyopia CorrectionRefractive ErrorAstigmatismImplantable Collamer LensMyopic Astigmatism CorrectionPostoperative Visual AcuitySurgical AstigmatismToric Intraocular Lens AlignmentUncorrected Visual AcuityVisual Acuity Recovery
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the left eye, the patient presented with a sudden decrease in visual acuity in the left eye. UCVA was 20/100 with a refraction of +2.50 -4.50 × 165°. We observed the toric marks with a 30° rotation from the original position and decided to reposition the TICL, obtaining a final UCVA of 20/25, which remained stable at 6 months' follow-up. TICL can present a considerable rotation that compromises visual acuity. The relocation of TICL is a safe and effective procedure to recover visual acuity due to significant spontaneous TICL rotation.