The Journal of the Acoustical Society of America · 1980 · 145 citations · 0 references
Health ProfessionsOtolaryngologyPhysicsAcousticsAuditory AnatomyOtologyCochlear AnatomyCochlear FunctionCochlear MechanicsInner Ear FunctionTympanic Membrane AnatomyAcoustic ImpedanceBasal Turn AnatomyCochlear Fluid MechanicsCochlear ImpedanceIntracochlear Pressure DynamicsMiddle Ear Pressure MeasurementMiddle Ear Transfer FunctionTympanic Membrane Mechanics
The authors developed calibrated, liquid‑filled, piezoelectric probe microphones to measure sound pressure in the basal turn of the cat cochlea, recording scala vestibuli and scala tympani pressures in 25 cats across 20–10 000 Hz tones. Intracochlear pressures were unaffected by the measurement technique, linearly related to tympanic membrane pressure up to 105 dB SPL, largely independent of probe depth, and exhibited a frequency‑dependent transfer ratio that peaks at 15–30 dB between 50–1000 Hz before declining, indicating that the middle ear provides a frequency‑dependent pressure gain; below 40 Hz the scala vestibuli and tympani pressures are equal and governed by round‑window compliance, whereas above 100 Hz the scala vestibuli pressure dominates, making the pressure difference across the cochlear partition approximately equal to the scala vestibuli pressure.
Techniques were developed for measuring sound pressure in the cochlea with calibrated, liquid-filled, piezoelectric probe microphones. Sound pressures were measured in scala vestibuli and scala tympani in the basal turn in 25 cats for tones from 20–10 000 Hz. Control experiments indicated that intracochlear pressures were essentially uninfluenced by the measuring technique, and were conducted to the cochlea via the ossicular chain. Intracochlear pressures are linearly related to pressure at the tympanic membrane for tone levels at least as high as 105 dB SPL, and are relatively independent of depth of probe insertion in the scalae. The transfer ratio of sound pressure in scala vestibuli to that at the tympanic membrane increases in magnitude over the frequency range 50–1000 Hz to reach a maximum value of 15–30 dB, and decreases at higher frequencies, thus demonstrating that the middle ear provides a frequency-dependent pressure gain. At frequencies below 40 Hz, the pressures in scala vestibuli and scala tympani are approximately equal and are both determined by the round-window membrane compliance. At frequencies above 100 Hz, the round-window membrane impedance is small compared to the acoustic input impedance of the cochlea, and the pressure in scala vestibuli considerably exceeds that in scala tympani; consequently, the pressure difference across the cochlear partition is approximately equal to the pressure in scala vestibuli.