Anesthesia & Analgesia · 1999 · 40 citations · 15 references
MedicineAnesthesiologySurgeryAnesthesiaPulmonologyVentilator ManagementBreathing SupportEndotracheal IntubationInvasive VentilationMechanical VentilationEndotracheal Intubation TimingEpinephrine ConcentrationHormonal Stress ResponsesLaryngeal Mask Airway DevicesLaryngeal Mask Airway UseRespiratory Stress ResponsesSystolic Blood Pressure
In a prospective, randomized, and controlled trial, we compared the stress responses after insertion of the Combitube[registered sign] (CT; Kendall-Sheridan Catheter Corp., Argyle, NY), the laryngeal mask airway (LMA), or endotracheal intubation (ET). Seventy-five patients scheduled for routine urological or gynecological surgery were randomly allocated to one of three groups and were ventilated via either an ET, a LMA, or a CT. All three devices could be inserted easily and rapidly, providing adequate ventilation and oxygenation. Insertion of the CT was associated with a significant increase in mean maximal systolic arterial pressure (160 +/- 32 mm Hg) and diastolic arterial pressure (91 +/- 17 mm Hg) compared with ET (140 +/- 24, 78 +/- 11 mm Hg; P < 0.05, P < 0.01, respectively) or insertion of the LMA (115 +/- 33, 63 +/- 22 mm Hg, both P < 0.001). The mean maximal epinephrine and norepinephrine plasma concentrations after insertion of the CT (37.3 +/- 31.1 and 279 +/- 139 pg/mL, respectively) were significantly higher than those after ET (35.8 +/- 89.8 and 195 +/- 58 pg/mL, respectively) or insertion of a LMA (17.3 +/- 13.3 and 158 +/- 67 pg/mL, respectively). This might be attributed to the pressure of the pharyngeal cuff of the CT on the anterior pharyngeal wall. We conclude that insertion of the CT causes a pronounced stress response and that precautions should be taken when used in patients at risk of hypertensive bleeding. Implications: In this study, we showed that the hemodynamic and catecholamine stress responses after insertion of the Combitube[registered sign] (Kendall-Sheridan Catheter Corp., Argyle, NY) were significantly higher compared with laryngeal mask airway or endotracheal intubation. We conclude that the increased stress response to insertion of a Combitube[registered sign] may represent a serious hazard to patients with cardiovascular disease. (Anesth Analg 1999;88:1389-94)
15
Difficult tracheal intubation in obstetrics
R. S. Cormack, J. R. Lehane · Anaesthesia · 1984 · 2.5K citations
Medicine, Anesthesiology, Obstetrics +10
Difficult tracheal intubation: a retrospective study
G. Samsoon, J. R. B. Young · Anaesthesia · 1987 · 1.6K citations · Full text
Medicine, Anesthesiology, Surgery +14
PLASMA CATECHOLAMINE RESPONSES TO TRACHEAL INTUBATION
D. R. Derbyshire, Aneta Chmielewski, David A. Fell et al. · British Journal of Anaesthesia · 1983 · 307 citations · Full text
The pressor response and laryngeal mask insertion
N. BRAUDE, Elizabeth Clements, U. M. HODGES et al. · Anaesthesia · 1989 · 161 citations
Medicine, Anesthesiology, Anesthesia +13