Acta Oto-Laryngologica · 2006 · 17 citations · 15 references
MedicineOtolaryngologyImage InterpretationLaryngologyOtolaryngologic SurgeryLaryngeal CancerLaryngeal ImagingAutofluorescenceAutofluorescence LaryngoscopyDiagnostic SensitivityEvaluation Of Laryngeal LesionsLaryngeal BiopsyLaryngeal PathologyLaryngoscopic DiagnosisLaryngoscopic Examination
CONCLUSION: Autofluorescent endoscopy (AFE) combined with microlaryngoscopy (MLS) gives a more accurate diagnosis of laryngeal pathology and can be further refined to minimize the need for MLS under general anaesthesia. OBJECTIVE: The aim of the present study was to evaluate the diagnostic potential and limitations of autofluorescent flexible laryngoscopy in comparison to MLS. PATIENTS AND METHODS: We examined 40 patients using the Pentax SAFE 1000 system. All patients then underwent direct MLS and biopsy under general anaesthesia. Biopsies were taken from areas that were visually suspicious and then from areas that showed disturbed autofluorescent signals. RESULTS: The overall sensitivity of AFE for various pathologies was 90.625%, while the sensitivity of MLS was 75%. Combining the findings of AFL and MLS we had a 100% diagnostic yield.
15
Autofluorescence of normal and malignant bronchial tissue
Jaclyn Y. Hung, Stephen Lam, Jean LeRiche et al. · Lasers in Surgery and Medicine · 1991 · 383 citations
Medicine, Cancer Biology, Oncology +17
Joel B. Epstein, C. Elizabeth Oakley, A. Millner et al. · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · 1997 · 114 citations
The Role of Transnasal Esophagoscopy in Head and Neck Oncology
Gregory N. Postma, Kevin K. Bach, Peter C. Belafsky et al. · The Laryngoscope · 2002 · 69 citations · Full text