Physics in Medicine and Biology · 2001 · 162 citations · 21 references
MedicineBiomedical EngineeringNeuroscienceElectrophysiologyNeuroanatomyNeurophysiologyBiopotential MeasurementElectrical CharacterizationElectrical ConductivityNervous TissueFrequency MeasurementFrequency-domain MeasurementNeural Electrodes
Resistivity values were measured from living human brain tissue in nine patients. A monopolar needle electrode was used with a measurement frequency of 50 kHz. Mean values were 3.51 Ohms m for grey matter and 3.91 Ohms m for white matter. Cerebrospiral fluid had a mean value of 0.80 Ohms m. Values for tumour tissues were dependent on the type of tumour and ranged from 2.30 to 9.70 Ohms m.
21
Measurement of Intraoperative Brain Surface Deformation under a Craniotomy
Calvin R. Maurer, Robert J. Maciunas, Robert J. Maciunas et al. · Neurosurgery · 1998 · 415 citations
Medicine, Neurosurgery, Surgery +14