Journal of Refractive Surgery · 1985 · 58 citations · 10 references
MedicineOphthalmologySurgeryAnterior SegmentOcular AnatomyOphthalmic SurgeryCorneal AnatomyCorneal OpticsCorneal TopographyAnterior Corneal CurvatureAstigmatic KeratotomyCorneal Curvature MeasurementCorneal Shape ChangesCorneal Thickness ChangesCorneal Topography ChangesLinear RegressionSurgical Operating Microscope Use
ABSTRACT: Twenty human cadaver eyes underwent partial depth corneal incisions under an operating microscope equipped with a Terry keratometer. A pattern of radial and tangential incisions originated by Dr. Luis Ruiz were made with a diamond knife at 3.0, 4.0, 5.0, and 6.0 mm optical zones. Keratometric readings were taken at various stages of the operation to better understand the dynamics of the technique. Tangential incisions were found to have different effects on the central corneal curvature at different optical zone sizes. The change in keratometric readings induced by the completed astigmatic keratotomy was measured at different optical zone sizes. A linear regression of the total change in diopters by keratometry to the size of the optical zone revealed a downward slope significant to the p<.001 level.
10
Surgical Correction of High Postkeratoplasty Astigmatism
Jay H. Krachmer · Archives of Ophthalmology · 1980 · 151 citations
Medicine, Ophthalmology, Surgery +12
Radial Keratotomy in Fresh Human Cadaver Eyes
James Salz, John S. Lee, James V. Jester et al. · Ophthalmology · 1981 · 63 citations
Medicine, Ophthalmology, Surgery +9