Loudon Surfactant Flood Pilot—Overview and Update

James R. Bragg, W. W. Gale, J. W. Canning

1983 · 15 citations · 2 references

Concepts

Abstract

ABSTRACT A successful surfactant (microemulsion) flood pilot test in a watered-out portion of the Weiler sand, Loudon Field, Illinois (USA) was completed in October, 1981. The microemulsion system tested was designed to be effective in the presence of high-salinity formation water containing 104,000 ppm (mg/l) total dissolved solids (TDS) without use of a preflush. The test was conducted in a single, 0.68-acre (2752 m2) 5-spot operated in a manner that approximated a confined pattern. The test was highly successful, recovering 60% of the oil remaining after waterflood. Cores from a post-flood well drilled within the pattern have confirmed the low final oil saturations and low surfactant retention achieved in the flood. Although oil recovery was excellent, loss of mobility control in the polymer drive bank and premature breakthrough of lower-salinity drive water were observed part-way through the test. Laboratory and field studies conducted since flood termination have confirmed that loss was caused by bacterial degradation of the xanthan biopolymer used. Several biocides were tested in the laboratory and in a field injection experiment to determine their effectiveness against the bacteria contaminating the pilot. Formaldehyde was shown to kill bacteria within the formation, have negligible adsorption on reservoir rock, and permit propagation of undegraded polymer. Based on these test results, formaldehyde should protect xanthan biopolymer from bacterial degradation in future microemulsion floods at Loudon.

References

2