Physica Scripta · 1988 · 15 citations · 4 references
EngineeringMaterials EngineeringMaterials ScienceElectromagneticsMechanical Behavior Of MaterialsMetallurgyAlloysFerrous MetallurgyMetalsSteel MaterialsCore Loss AnalysisCore Loss ReductionCore LossesElectrical SteelsHigh PermeabilityIron LossesMagnetic LossesMagnetostriction
This paper is concerned with the new heatproof domain refining method for the high permeability grain oriented electrical steel, and the magnetic-properties of the materials using this method are described. Loss reductions of up to 18% are possible when using the techniques on suitable materials. In order to obtain the lowest iron loss, it is necessary to use high B8 and thinner gauge material. Also good wound core loss performance was obtained by using small non-cut rectangular wound cores. Especially, in the case of thinner gauge (7 mil thickness), the mean value of the core losses was 0.221 W/lb at 1.3 T/60 Hz. This value is about 1.5 times that of the amorphous transformer. The magnetostriction characteristics of the material are almost the same as that of the commercial HI-B.
4