Mean IAP in critically ill children is 7 +/- 3 mm Hg. The minimum optimal volume needed to accurately measure IAP by the intravesical method in children is 3 mL. We recommend that 3 mL be the standard instillation volume for IAP measurement by the intravesical method in children. IAP >10 mm Hg should be considered elevated in children.