International Journal of Electrical Engineering Education · 2002 · 21 citations · 16 references
EngineeringElectrical EngineeringComputer-aided DesignDesign OptimizationPower ElectronicsPower System DesignReverse EngineeringTransformer DesignWinding Design
A reverse approach to designing as-built transformers is presented in this paper. The physical characteristics and dimensions of the windings and core are the specifications. By manipulating the amount and type of material actually to be used in the construction of the transformer, its performance can be determined. Such an approach is essentially the opposite of the conventional transformer design method. The method is applied to two sample high voltage transformers. The measured performance of the transformers verifies the usefulness of using this reverse design approach.
16
A full procedure to model high frequency transformer windings
R. Asensi, J.A. Cobos, O. García et al. · 2002 · 94 citations
Journal of the Franklin Institute · 1954 · 92 citations · Full text