An Open-Loop Technique to Facilitate Microtubal Anastomoses in the Rat

Sun Lee, Sobhi A. Hweidi, William P. Skivolocki

Journal of Reconstructive Microsurgery · 1984 · 13 citations · 0 references

Concepts

Abstract

Open-loop suture technique was employed for microvascular anastomoses in the rat to facilitate surgery and to avoid inadvertently catching opposite side vessel walls with the needle. A moderately trained microsurgeon performed carotid and femoral arterial anastomoses, and conventional and open-loop suture techniques were compared. A 100% patency rate was obtained in the open-loop series of 280 end-to-end anastomoses, and this technique was 24 to 25% faster than conventional suturing.