Transfusion · 1994 · 69 citations · 4 references
MedicineHematologyQuality ManagementHealthcare Quality ImprovementPatient SafetyTransfusion MedicineBlood Component TherapyBlood Transfusion ManagementBlood Transfusion SafetyRed Blood Cell TransfusionTransfusion SupportTransfusion TherapyBlood Component CompatibilityInstitutional Policy FrameworksOversightRed Blood Cell Transfusion SafetyTransfusion Error PreventionTransfusion Quality AssuranceTransfusion Quality ImprovementTransfusion Service Quality Control
Data from New York State and nationwide estimates indicate that ABO‑incompatible transfusions occur at a rate of about 1 in 33,000 units, with most errors stemming from transfusionist misidentification rather than laboratory mistakes. The authors implemented a quality assessment/quality improvement process that directly monitored transfusionist practices and evaluated institutional blood‑administration policies. Initially, 50 % of transfusions deviated from policy, but after the QA/QI intervention the deviation rate fell to almost zero, demonstrating that such monitoring can enhance transfusion safety.
BACKGROUND: Data from New York State indicate that about 1 of every 33,000 red cell units transfused is ABO‐incompatible with the recipient. National application of these data suggests that as many as 360 ABO‐incompatible whole blood and red cell transfusions might occur annually in the United States. Phlebotomy and blood bank laboratory errors cause some of these ABO‐incompatible transfusions, but the greatest number result either partially or solely from the failure of transfusionists to identify properly either a patient or the blood component a patient receives. STUDY DESIGN AND METHODS: A quality assessment/quality improvement (QA/QI), process is described that allowed for the direct oversight (monitoring) of transfusionists' practices and for the assessment of institutional policies for blood administration. RESULTS: At the beginning of the QA/QI process, monitoring of blood administration practices revealed that a variance from institutional blood administration policy occurred during 50 percent of blood and component transfusions. As a result of the QA/QI process, the percentage of transfusions with an associated variance from institutional policy dropped to nearly zero. CONCLUSION: The QA/QI process described in this report, or one similar to it, could improve transfusion safety and serve as a model for increased involvement by transfusion service medical directors in the oversight of transfusionists' practices.
4
Reports of 355 transfusion‐associated deaths: 1976 through 1985
Kathleen Sazama · Transfusion · 1990 · 736 citations
A report of 104 transfusion errors in New York State
Jeanne V. Linden, B Paul, K.P. Dressler · Transfusion · 1992 · 329 citations
Collection and Transfusion of Blood in the United States, 1982–1988
Douglas M. Surgenor, Edward L. Wallace, Steven H.S. Hao et al. · New England Journal of Medicine · 1990 · 250 citations · Full text
Medicine, Health Policy, Hematology +13