Spine · 2006 · 154 citations · 29 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsSpinal BiomechanicsSpine SurgeryCervical Spine BiomechanicsIntervertebral Disc BiomechanicsSpinal FusionSpinal Motion AnalysisSpinal Motion SegmentsSpinal Range Of MotionBiomechanical EffectsCervical Spine MotionMotion CompensationSegmental Axial RotationSegmental Lateral BendingSegmental Motion AssessmentSegmental Range Of MotionSegmental Spinal Motion
In Brief Study Design. Seven adult human cadaveric cervical spines (C2–T1) were biomechanically tested in a programmable testing device. Objective. Compare the effects of incremental single-level fusion at different levels of the cervical spine. Summary of Background Data. Clinical studies have reported degenerative symptomatic disc disease at disc levels adjacent to fusion. No known study has attempted to delineate the effects of single-level fusion at different levels of the cervical spine. Methods. The spines were tested in flexion, extension, right and left lateral bending, and right and left axial rotation for 7 different conditions: harvested and 6 independent single-level fused conditions (i.e., C2–C3, C3–C4, C4–C5, C5–C6, C6–C7, and C7–T1). Segmental motion and global stiffness data were normalized to the harvested condition and compared using a 1-way analysis of variance followed by a SNK test (P < 0.01). Results. Motion compensation was distributed among the unfused segments with significant compensation at the segments adjacent to fusion. Significant increases occurred at the level above C3–C4 and C4–C5 fusions, and below for C5–C6 and C6–C7 fusions in both flexion and extension. Conclusions. Increase motion compensation occurred at segments immediately adjacent to a single-level fusion. Significant differences occurred at the level above the fusion site for the C3–C4 and C4–C5 fusion in both flexion and extension. When the lower levels (C5–C6, C6–C7) were fused, a significant amount of increased motion was observed at the levels immediately above and below the fusion. However, greater compensation occurred at the inferior segments than the superior segments for the lower level fusions (C5–C6, C6–C7). The biomechanical effects of single-level cervical fusion were studied. When the lower levels (C5–C6, C6–C7) were fused, a significant increase in motion occurred at levels immediately above and below the fusion. Furthermore, greater compensation occurred at the inferior segments than the superior segments when the lower levels were fused.
29
Guy L. Odom · Journal of the American Medical Association · 1958 · 513 citations
Intradiscal Pressure Measurements Above an Instrumented Fusion
Susan L. Weinhoffer, Richard D. Guyer, Morley A. Herbert et al. · Spine · 1995 · 396 citations