IEEE Transactions on Industrial Electronics · 2008 · 128 citations · 25 references
EngineeringElectrical EngineeringElectric MachinesPower ElectronicsPowertrain EngineeringDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsPermanent Magnet MachinesElectric Machine DrivesElectric Motor ControlField WeakeningInterior Permanent Magnet Synchronous MachinesOperating Point ControlPermanent Magnet Synchronous MachinesPermanent Magnet Synchronous Motor DrivesPermanent Magnet Synchronous Motors
In this paper, first, the effect of the interior permanent-magnet synchronous-motor (IPMSM) stator resistance to the maximum available motoring or regenerative braking torque is clarified. Then, a drive operating point is interpreted geometrically as the intersecting point of the torque-demand curve with either the maximum torque per ampere (MTPA) trajectory or the voltage-constraint curve inherently imposed by the motor and inverter under different control modes. Based on this principle, a novel voltage-constraint-tracking (VCT) field-weakening control scheme for IPMSM drives is proposed. The proposed method can automatically determine the desired MTPA or field-weakening control modes and provide a smooth transition between these two modes. No machine parameters are required in the field-weakening control mode, and no dc-link voltage sensor is used, rendering the proposed scheme rather robust. In addition, the minimum copper-loss operation can be preserved in the VCT-based control to achieve high efficiency. The proposed control method has a simple structure so that it can easily be implemented by modifying a conventional vector-controlled drive system for practical applications. Finally, a DSP-based prototype drive is constructed to verify the feasibility of the proposed scheme, and some experimental results are provided to demonstrate the satisfactory features.
25