IEEE Transactions on Microwave Theory and Techniques · 2013 · 72 citations · 10 references
EngineeringElectrical EngineeringPhysicsElectromagneticsElectromagnetismWireless CommunicationsElectromagnetic CompatibilityElectromagnetic MethodsElectromagnetic PowerMagnetic Circuit AnalysisResonance In CircuitsWireless Power TransferBiomedical Wireless Power TransferDosimetry ModelingFinite Difference Time Domain ModelingImpedance ModelingMagnetic Resonant CouplingResonant Energy TransferResonant Power TransferSpecific Energy Absorption
We conducted a dosimetry study of a wireless power transfer (WPT) system, which is based on magnetically coupled resonances. The electric and magnetic fields produced by the system have been calculated using the method of moments. We calculated the induced electric fields and the specific absorption rates in a Japanese adult male model by the scattered-field finite-difference time-domain method, taking into account both the incident electric and magnetic fields, and also by the impedance method, but only taking into account the incident magnetic fields. We discuss the differences between the results obtained by the two methods. We also discuss the compliance of the WPT system with international safety guidelines.
10
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
André Kurs, Aristeidis Karalis, Robert Moffatt et al. · Science · 2007 · 5.5K citations · Full text
Tomoaki Nagaoka, Soichi Watanabe, Kiyoko Sakurai et al. · Physics in Medicine and Biology · 2003 · 773 citations