Journal of Energy · 1978 · 34 citations · 4 references
EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesHeat TransferThermal AnalysisCooling SystemsElectric MotorsHeat Transfer In FluidsMachine CoolingThermal DesignThermal ManagementElectric Motor CoolingHeat Pipe TechnologyHeat PipesHeat Transfer In Electrical MachinesMotor CoolingRotor CoolingStator CoolingThermal Management Of Electric Machines
Two types of copper/water heat pipes have been developed for cooling of both the rotor and the stator of an asynchronous electric motor which shall be used as a high-performance locomotive drive. For the stator axial groove heat pipes are used with a slight liquid overfill. The rotor heat pipes have cirumferential grooves and require a minimum liquid fill charge of about 20% of the heat pipe volume to effectively cool the rotor between 0 and 5000 rpm. Experimental results obtained from individual heat pipes and from a rotor model demonstrated that the heat pipes are able to effectively cool the electric motor. Calculations showed that about 75% of the dissipated heat will be transferred by the heat pipes to the ultimate air-convection heat sink.
4
IEEE Power Engineering Review · 1985 · 499 citations
Engineering, Computer Engineering, Electrical Engineering +3
Heat Pipe Cooled Induction Motor
J. C. Corman, R. C. Edgar, Michael H. McLaughlin et al. · IEEE Transactions on Power Apparatus and Systems · 1974 · 19 citations
Cooling of electrical machines by heat pipes
O. Oslejsek, F. Polášek · 1976 · 12 citations
Engineering, Electrical Engineering, Mechanical Engineering +14