British journal of surgery · 1991 · 143 citations · 6 references
MedicineRadiologySurgeryDiagnostic ImagingUltrasonographyUltrasoundAbdominal UltrasonographyAortic ImagingDiagnostic UltrasonographyVascular ImagingVascular UltrasonographyVascular UltrasoundAbdominal Aorta ImagingAbdominal Aorta UltrasoundAbdominal Aortic UltrasonographyAortic Diameter AssessmentAortic Diameter SurveillanceAortic Disease SurveillanceRepeatabilityUltrasound Of The Aorta
The repeatability, observer bias and instrument bias of aortic diameter measurement by ultrasonography, were investigated in ten patients with small (3-6 cm by computed tomography) infrarenal abdominal aortic aneurysm. The repeatability of maximum aortic diameter measurement by ultrasonography was much better for anterior-posterior than transverse diameter, with coefficients of repeatability 3.0-7.5 mm and 10-15 mm respectively. The repeatability of suprarenal aortic diameter measurement was poor. Surprisingly, maximum diameter using ultrasonography was larger than that using computed tomography, the difference being least for anterior-posterior measurements. At best a single, experienced observer, using the same instrument may provide aortic diameters using ultrasonography accurate to within 5 mm, but more commonly such aortic diameter is only accurate to within 8 mm.
6
Prognosis of Abdominal Aortic Aneurysms
Martin P. Nevitt, David Ballard, John W. Hallett · New England Journal of Medicine · 1989 · 492 citations
OXFORD SCREENING PROGRAMME FOR ABDOMINAL AORTIC ANEURYSM IN MEN AGED 65 TO 74 YEARS
J Collin, Jackie Walton, Leandro Coelho de Araújo et al. · The Lancet · 1988 · 333 citations
Routine ultrasound screening in management of abdominal aortic aneurysm
R A P Scott, H A Ashton, D. Kay · BMJ · 1988 · 46 citations · Full text