Radiation Protection Dosimetry · 2006 · 19 citations · 7 references
MedicineNuclear EngineeringRadiation DosimetryRadiation ProtectionRadiation SafetyAbsorbed DoseEquivalent DoseRadiation Dose MeasurementRadioactive DecayRadiological Risk AssessmentDose AssessmentDose Equivalent MeasurementEquivalent Dose DeterminationIonizing Radiation DosimetryNatural Radioactivity MeasurementRadiation Dose AssessmentRadiation Protection DosimetryRadioactivity Measurement
Annual effective dose equivalent due to natural gamma radiation from (238)U, (232)Th and (40)K have been evaluated from granites in Turkey. Forty samples were taken for spectrometric analysis. Specific concentrations of (238)U, (232)Th and (40)K in granite samples were determined. Spectroscopy system was used with 1.8 keV (FWHM) coaxial high purity germanium (HPGe) detector. Average values of concentrations of (238)U, (232)Th and (40)K were detected at 15.85, 33.76 and 359 Bq kg(-1), respectively. The average value of radon varies from 0.073 to 0.185 Bq m(-2) h(-1) exhalation depends on the specific concentration of uranium. The dose rate due to this highest activity which have been evaluated by a Monte Carlo transport calculations does not exceed 0.4 mSv a(-1).
7
The United Nations Scientific Committee on the Effects of Atomic Radiation