EngineeringInfectious DiseasesSurgeryComputational Fluid DynamicsFluid DynamicsVentilationAirflow DistributionAirflow SimulationMechanical VentilationVentilation ModelingVentilation System DesignVentilation SystemsAirflow ControlComputational Fluid Dynamics ValidationHospital VentilationOperating Room Ventilation DesignRoom Air DistributionRoom Airflow SimulationVentilation PerformanceVentilation Simulation Models
In Brief BACKGROUND: A negative-pressure operating theater is required to limit the spread of respiratory diseases in patients with severe acute respiratory syndrome, tuberculosis, avian influenza, or similar infectious diseases. In Hong Kong, we converted a conventional operating theater into a negative-pressure operating theater that has been in service for more than a year. In this article, we introduce its ventilation design and evaluate the airflow performance in relation to different combinations of medical lamp configurations and modes of launching infectious particles into the room air. METHODS: We used a computational fluid dynamics technique for the numerical analysis. RESULTS: Our analyses showed that the airflow performance in the negative-pressure operating theater was satisfactory and comparable to the original positive-pressure design. The airflow pattern effectively controlled the dispersion of infectious particles. Our calculations demonstrated that the airflow contained the dispersion of infectious particles released from the patient sufficiently to protect the surgical team, and vice versa. CONCLUSIONS: Computational fluid dynamics can be used to assess airflow in a negative-pressure operating room and model the dispersion of infectious particles from the patient. IMPLICATIONS: A negative-pressure operating theater may help limit the spread of air-borne infections from patients with respiratory disease. This article describes the ventilation design of a specific case and evaluates its airflow performance using computer simulation.
7
WH Seto, Dominic N.C. Tsang, Rwh Yung et al. · The Lancet · 2003 · 882 citations · Full text
Public Health, Infectious Disease Control, Infectious Diseases +13
Performance of ventilation system in a non-standard operating room
T.T. Chow, Xiaoyu Yang · Building and Environment · 2003 · 122 citations
Engineering, Surgery, Hvac Systems +13
Tracheostomy in a patient with severe acute respiratory syndrome
Alan Kwan, W.G. Fok, KI Law et al. · British Journal of Anaesthesia · 2004 · 60 citations · Full text
Medicine, Surgery, Pulmonology +8