Electromagnetics · 2009 · 32 citations · 16 references
EngineeringBiophysicsComputational Heat TransferHeat TransferPhysiological Systems ModelingAbsorption In TissueAbsorption ModelingRadiative Heat TransferRadiative TransferFinite Difference Time Domain ModelingFinite Difference Time Domain SimulationHuman Body Radiation AbsorptionRadiative Transfer ModelingSpatial Correlation StructureThreshold Behavior
Abstract The influence of specific absorption rate averaging schemes on the spatial correlation between mass-averaged specific absorption rate and radio-frequency-induced steady-state temperature-rise distributions in the “Visible Human” body model exposed to plane waves in the 30–800 MHz frequency range is investigated through finite-difference time-domain modeling. The averaged specific absorption rate is computed on the basis of the IEEE Std. C95.3-2002 specific absorption rate mass-averaging algorithm, employing 1-g and 10-g averaging tissue masses and several air-inclusion factors. The analysis reveals that the 10-g average specific absorption rate yields larger global correlation with the corresponding radio-frequency-induced temperature-rise distribution for the considered plane-wave exposures, while the dependence on the air-inclusion factor features a distinctive threshold behavior.
16