Journal of Pressure Vessel Technology · 2005 · 44 citations · 12 references
EngineeringMechanical EngineeringPhysicsFluid DynamicsFluid MechanicsVibrationAeroelastic TestingFlow StabilityHydrodynamic ResponseHydrodynamic StabilityAeroelastic VibrationDynamic ResponseExperimental Aeroelastic TestingTube BendingTurbulence ExcitationTwo-phase Flow RegimesTwo-phase Pipe FlowWork Rate Response
The dynamic response of U-tubes to two-phase cross-flow has been studied in tests involving a simplified U-tube bundle with a set of flat-bar supports at the apex, subjected to air–water cross-flow over the mid-span region. Tube vibration and the interaction between tubes and supports were measured over a wide range of void fractions and flow rates, for three different tube-to-support clearances. The vibration properties and tube-to-support work-rates could be characterized in terms of the relative influence of fluidelastic instability and random-turbulence excitation. For the first time, in a U-bend tube bundle with liquid or two-phase flow, fluidelastic instability was observed both in the out-of-plane and in the in-plane direction. This raises the possibility of higher-than-expected tube-to-support work-rates for U-tubes restrained by flat bars, particularly if fluidelastic instability, random turbulence and loose supports combine adversely.
12
Flow-induced vibration: recent findings and open questions
M. J. Pettigrew, Colette E. Taylor, N. J. Fisher et al. · Nuclear Engineering and Design · 1998 · 154 citations
S.J. Green, G. Hetsroni · International Journal of Multiphase Flow · 1995 · 126 citations