Concepedia

Publication | Closed Access

Mold filling analysis in resin transfer molding

32

Citations

10

References

1996

Year

Abstract

Abstract This study is a comparison of independently designed mold flow experiments performed at The Dow Chemical Company with simulations from a computer code developed at The Ohio State University. The experiments used in the validation study included isothermal 1‐dimensional flow with line gating and end venting, isothermal 2‐dimensional flow with converging flow and center venting, and two different resin systems. The simulation results were compared with experimental pressure and temperature readings and fill times. It was found that simulated fill times could be predicted within experimental error and pressure distributions could be predicted with the application of a scaling factor.

References

YearCitations