Clinical Chemistry · 2009 · 277 citations · 16 references
MedicinePathobiologyPathologyDiagnostic PathologyMolecular DiagnosticsMolecular PathologyAmyloid FormationAntibody CharacterizationBiomarkers In PathologyEnzyme-linked Immunosorbent AssayMicroscopic ExaminationAgarose Gel ElectrophoresisAmyloidogenic ProteinsImmunofixation ElectrophoresisImmunoglobulin Light Chain AmyloidosisImmunoglobulin Light Chain DiseaseLight Chain AnalysisSerum BiomarkersSerum Free Light Chain Assay
BACKGROUND: The diagnosis of systemic immunoglobulin light-chain (AL) amyloidosis requires demonstration of amyloid deposits in a tissue biopsy and amyloidogenic monoclonal light chains. The optimal strategy to identify the amyloidogenic clone has not been established. We prospectively assessed the diagnostic sensitivity of the serum free light chain (FLC) kappa/lambda ratio, a commercial serum and urine agarose gel electrophoresis immunofixation (IFE), and the high-resolution agarose gel electrophoresis immunofixation (HR-IFE) developed at our referral center in patients with AL amyloidosis, in whom the amyloidogenic light chain was unequivocally identified in the amyloid deposits. METHODS: The amyloidogenic light chain was identified in 121 consecutive patients with AL amyloidosis by immunoelectron microscopy analysis of abdominal fat aspirates and/or organ biopsies. We characterized the monoclonal light chain by using IFE and HR-IFE in serum and urine and the FLC kappa/lambda ratio in serum. We then compared the diagnostic sensitivities of the 3 assays. RESULTS: The HR-IFE of serum and urine identified the amyloidogenic light chain in all 115 patients with a monoclonal gammopathy. Six patients with a biclonal gammopathy were omitted from the statistical analysis. The diagnostic sensitivity of commercial serum and urine IFE was greater than that of the FLC kappa/lambda ratio (96% vs 76%). The combination of serum IFE and the FLC assay detected the amyloidogenic light chain in 96% of patients. The combination of IFE of both serum and urine with the FLC kappa/lambda ratio had a 100% sensitivity. CONCLUSIONS: The identification of amyloidogenic light chains cannot rely on a single test and requires the combination of a commercially available FLC assay with immunofixation of both serum and urine.
16
Jerry A. Katzmann, Raynell Clark, Roshini S. Abraham et al. · PubMed · 2002 · 620 citations
Jerry A. Katzmann, Raynell Clark, Roshini S. Abraham et al. · Clinical Chemistry · 2002 · 615 citations · Full text
Helen J. Lachmann, R Gallimore, Julian D. Gillmore et al. · British Journal of Haematology · 2003 · 433 citations · Full text
Jan Olof Jeppson, C.‐B. Laurell, Bo Franzén · Clinical Chemistry · 1979 · 287 citations