MedicineOncologyRadiation OncologyRadiation DosimetryRadiation ProtectionRadiobiologyBiological Effects Of RadiationRadiation SensitivityRadiation TherapyRadiation ToxicityRadiobiological ConsiderationsRadiotherapy For Skin CancerFractionationRadiation Dose EffectsRadiation Dose ReductionRadiation Field DesignRadiation Fractionation EffectsRadiosensitization By FractionationTherapeutic DosimetryX-ray Dosimetry
To decrease the effects of x-rays on the skin when large fields are used to reach a deep-seated cancer, Alban Köhler (1) in 1909 had devised what has been termed “fractionation of the x-ray dosage in space.” This was done by placing on the skin a steel wire net, the openings of which were 2 mm. wide and the wire proper 1 mm. in thickness. Köhler administered massive doses, ten to twenty times the total dose usually given at that time through a conventional open field. Healing of the skin was initiated in and extended from the surrounding relatively unscathed normal skin. In experimental radiobiology in 1931 (2) and 1938 (3a), doses of 25,000 r and 120,000 r without a grid were found to be inhibitory and lethal respectively to the proliferation of normal tissue in vitro, the cancericidal dose in vivo being 24,000 r in air (3b). In the above case, the optimum dose without a grid enters the tumor-bearing area, while in the grid method only 40 per cent of the 24,000 r in air, or 9,600 r in air, enters the tumor-bearing area to produce a lytic effect. In 1933 Frank Liberson (4) introduced the reciprocal, perforated screen made of lead 2 mm. in thickness with round apertures 3 mm. in diameter. Haring (5), in 1934, used grids made of lead, and Grynkraut (6), in 1935, employed grids of lead with aluminum foil lining. In the author's experience, none of the grids enumerated above served to safeguard the skin from the impact of large x-ray doses in cases of deep-seated tumors: first, because of the absorption in the skin of considerable quantities of characteristic secondary rays from the lead; secondly, because of a disproportionate ratio of open (irradiated) to covered (non-irradiated) zones. This resulted in tipping the scales in favor of destruction as against regeneration in the normal tissues. By adopting lead-rubber as the material out of which the grids were fashioned, thus eliminating the secondary rays from lead (7), and by empirically establishing the proportion of open to covered sections in the grid at 40 to 60 per cent (8, 9), the author began to approximate the goal he set for himself, namely, the sterilization of large, deep-seated tumors. The apertures in the grid measured 1.5 cm., 1 cm., and 0.5 cm. square or in diameter. It was further proved empirically that placing the grid in the same position at each treatment constituted an advantage over the alternating method, in that optimum doses could thus be delivered. The average daily dose, corresponding to the volume, depth, and sensitivity of the tumor, ranges from 400 and 600 to 800 r in air, the total dose through a single field being 10,000 r in air with a 20 × 20-cm. grid and 12,000 r in air with a 10 × 15-cm. grid. The smaller the volume of tissue irradiated, the higher the total dose. Thus, in some sites, e.g., the cervical region, to avoid cross-firing one may attain a cancericidal dose through a single field by gradually narrowing the port of entry as the tumor regresses.
4
Optimal Skin Tolerance Dose Levels
B. Jolles, R. G. Mitchell · British Journal of Radiology · 1947 · 54 citations
The Value of a Multi-perforated Screen in Deep X-ray Therapy
Frank Liberson · Radiology · 1933 · 50 citations