Design of Steam-Stripping Columns for Removal of Volatile Organic Compounds from Water Using Random and Structured Packings

J. Castillo, G. Guerrero-Medina, J. Lopez-Toledo, João Rocha

Industrial & Engineering Chemistry Research · 2000 · 21 citations · 10 references

Concepts

Abstract

Mass-transfer data at different feed and steam rates, using structured and random packings, have been collected to develop a model for the design or analysis of packed columns for stripping of volatile organic compounds (VOCs) from water. The steam-stripping experiments were conducted in a stainless steel column of 0.245-m internal diameter, with 2.8 m of packed section. The packings used were Sulzer BX gauze structured packing, Mellapak 250Y structured packing, 1-in. Flexirings, and 1-in. Fleximax random packing. The VOCs were chloroform (CH 3 Cl) and toluene (C 7 H 8 ). The model considers the simultaneous occurrence of mass transfer and hydraulic phenomena with the same expressions for liquid and vapor mass-transfer coefficients and the same expression for effective interfacial area with one constant for each packing. The average deviation for the measured and calculated volumetric mass-transfer coefficient and effective height of packing is 0.29 and 0.23, respectively.

References

10