Journal of Refractive Surgery · 2012 · 133 citations · 22 references
MedicineOphthalmologySurgeryBiomedical OpticsOphthalmic SurgeryRefractive SurgeryCataract SurgeryOcular BiometryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorRefractive Error AssessmentAxial Length Prediction ModelsIol Power CalculationLens BiometryPostoperative RefractionPostoperative Visual AcuityPostoperative Visual Outcome AssessmentRefractive Cataract SurgerySpherical Equivalent Refraction
PURPOSE: To compare intraocular lens (IOL) power calculation and refractive outcome between patients who underwent laser refractive cataract surgery with a femtosecond laser and those with conventional cataract surgery. METHODS: In this prospective study, 77 eyes from 77 patients underwent laser refractive cataract surgery (laser group; Alcon LenSx femtosecond laser), and conventional cataract surgery with phacoemulsification was performed in 57 eyes from 57 patients (conventional group). Biometry was done with optical low coherence reflectometry (Lenstar LS900, Haag-Streit AG), and IOL calculation was performed with third-generation IOL formulas (SRK/T, Hoffer Q, and Holladay). The refractive outcome was analyzed using the mean absolute error (MAE; difference between predicted and achieved postoperative spherical equivalent refraction), and multivariable regression analysis was performed to compare the two groups. RESULTS: No significant differences were found between age, axial length, keratometry, and preoperative corrected visual acuity in the laser and conventional groups (P>.05; Mann-Whitney U test). At least 6 weeks after surgery, MAE was significantly lower in the laser group (0.38±0.28 diopters [D]) than in the conventional group (0.50±0.38 D) (P=.04). The difference was the greatest in short (axial length <22.0 mm, 0.43±0.41 vs 0.63±0.48) and long (axial length >26.0 mm, 0.33±0.24 vs 0.63±0.42) eyes. CONCLUSIONS: Laser refractive cataract surgery with a femtosecond laser resulted in a significantly better predictability of IOL power calculation than conventional phacoemulsification surgery. This difference is possibly due to a more precise capsulorrhexis, resulting in a more stable IOL position.
22
Sources of error in intraocular lens power calculation
Sverker Norrby · Journal of Cataract & Refractive Surgery · 2008 · 656 citations
Medicine, Ophthalmology, Surgery +17
Sources of error in intraocular lens power calculation
Thomas Olsen · Journal of Cataract & Refractive Surgery · 1992 · 496 citations
Medicine, Ophthalmology, Surgery +17
Petros Aristodemou, Nathaniel E. Knox Cartwright, J M Sparrow et al. · Journal of Cataract & Refractive Surgery · 2010 · 329 citations
Medicine, Ophthalmology, Surgery +17