IEEE Transactions on Microwave Theory and Techniques · 1968 · 13 citations · 6 references
EngineeringElectrical EngineeringInstrumentationMetrologyMicrowave EngineeringCalibrationEquipment CalibrationMeasurement ErrorMeasurement StandardsMicrowave MeasurementsNoise MeasurementMicrowave Attenuator DesignMicrowave RadiometryNoise CalibrationNoise SourcesRadiometer Calibration
The chief possible causes of error in the calibration of microwave noise sources are examined and a radiometer designed to minimize these errors is described. This includes a self-contained hot-load standard, facilities for measuring the hot-guide losses, a synchronously switched broad-band circulator, a switchable, high-stability attenuator, provision for measuring this attenuation, and a carbon-filament lamp reference noise source.
6
Absolute Measurement of Temperatures of Microwave Noise Sources
A. J. Estin, C. L. Trembath, J. S. Wells et al. · IRE Transactions on Instrumentation · 1960 · 19 citations