Diabetes Care · 1983 · 34 citations · 0 references
MedicineEndocrinologyInternal MedicineCircadian RhythmsDiabetologyPharmacokinetic VariabilityBlood Glucose MonitoringDiabetes ManagementDiabetes MellitusGlycemic ControlGlycemic MonitoringInsulin TherapyContinuous Subcutaneous InfusionContinuous Subcutaneous Insulin InfusionFasting GlycemiaGlucose MonitoringInfusion Rate EffectsInsulin MetabolismPrandial Insulin Administration
The plasma glucose and plasma free insulin profiles of six totally insulin-dependent diabetic patients were compared during periods of 4 days in hospital under a conventional insulin therapy (ICIT) comprising 4 daily injections of regular insulin and under continuous subcutaneous insulin infusion (CSII). Two profiles of prandial insulin administration with CSII were compared: a rectangular (R) and an exponential wave (E) in which 50% of the dose was given rapidly followed by an exponential decrease. In both cases, the basal infusion rate was increased by 30-50% between 5 a.m. and 8 a.m. Mean circadian blood glucose was equally good with ICIT: R and E: 7.0 +/- 0.9, 7.3 +/- 1.0, and 7.1 +/- 1.0 mmol/L, respectively. In five patients, fasting plasma glucose was higher with ICIT than with R and E (12.7 +/- 1.8 versus 6.9 +/- 1.0 and 6.8 +/- 0.8 mmol/L, respectively; t test: P less than 0.05; Wilcoxon: P = 0.06). Mean plasma free insulin level was significantly higher (t test: P less than 0.005; Wilcoxon: P less than 0.05) with ICIT (0.46 +/- 0.04 nmol/L) than with R (0.37 +/- 0.04 nmol/L) or E (0.36 +/- 0.05 nmol/L), although the daily doses were similar. In conclusion, CSII leads to a better glycemic control than ICIT, since it appears to prevent the morning rise of blood glucose.