Publication | Closed Access
Predictability of creatinine clearance estimates in critically ill patients
130
Citations
0
References
1993
Year
The utilization of the Cockcroft-Gault equation as used clinically (the lower of ideal or total body weight and the higher of actual serum creatinine or corrected serum creatinine concentration to 1 mg/dL [85 mumol/L]) results in more accurate predictions of glomerular filtration rate in the medical, critically ill patient than urine creatinine clearance measures. If creatinine clearance measures are used, the 30-min collection provided results not different from those results obtained with 24-hr urinary collections.