Catheterization and Cardiovascular Interventions · 2001 · 21 citations · 16 references
MedicineCardiologySurgeryInterventional CardiologyMicrosurgeryVascular SurgeryCoronary Artery SurgeryEndovascular SurgeryPercutaneous Coronary InterventionStent PlacementVascular AnastomosisCoronary StentingExpanded Polytetrafluoroethylene MembranesRestenosis After StentingSaphenous Vein GraftingVascular StentingVein Graft AnastomosisVenous Bypass GraftingVenous Bypass Surgery
The restenosis rate after stenting of lesions in aortocoronary venous bypass grafts still has to be considered unsatisfactorily high. We investigated a new stent design characterized by an expandable polytetrafluorethylene (PTFE) membrane in between two layers of struts. Five consecutive male patients (age 70 +/- 6 years) were followed prospectively who presented with at least two de novo lesions in different grafts 13 +/- 3 years after bypass surgery. A total of 11 lesions were treated located in grafts anastomosed to the circumflex (n = 3), to the LAD (n = 7), and to the right coronary artery (n = 1). Within the same procedure, every patient received membrane-covered stents (n = 6) and conventional stents (n = 5) in either of their lesions. All patients underwent successful interventions. The minimal luminal diameter increased from 1.0 +/- 0.5 to 2.9 +/- 0.6 mm in lesions treated by the membrane-covered stents and from 0.8 +/- 0.4 to 2.4 +/- 0.7 mm in the lesions treated by conventional stents. During follow-up, four out of five patients required angioplasty for in-stent restenosis of lesions covered by a conventional stent, whereas no patient underwent revascularization for a lesion treated by a membrane-covered device. The mean minimal luminal diameter of lesions covered by a conventional stent decreased by 42% to 1.4 +/- 0.6 mm; the mean minimal luminal diameter of the lesions treated by a stent graft declined by 9% to 2.8 +/- 0.6 mm (P < 0.05). This series of intraindividual comparisons suggests that membrane-covered stents may have the power to reduce in-stent restenosis in obstructed aortocoronary venous bypass grafts.
16
Fifteen hundred coronary reoperations
Bruce W. Lytle, Floyd D. Loop, Delos M. Cosgrove et al. · Journal of Thoracic and Cardiovascular Surgery · 1987 · 276 citations
Medicine, Cardiology, Surgery +12
Coronary bypass graft fate: Long-term angiographic study
Gerald M. FitzGibbon, Alan J. Leach, Henryk Kafka et al. · Journal of the American College of Cardiology · 1991 · 236 citations
Medicine, Cardiology, Surgery +14