The Structural Design of Tall and Special Buildings · 2003 · 83 citations · 0 references
EngineeringBuilding ScienceCivil EngineeringBuilding StructuresStructural DynamicsStructural EngineeringBuilding AerodynamicsDamped VibrationDynamic Structural ResponseEnergy Dissipation DevicesStructural DampingWind-induced VibrationDampingDamping SystemsDesign CriteriaSupplemental DampingSupplemental Damping DevicesSupplemental Damping SystemsSuppression Of Wind-induced VibrationViscous Dampers
Abstract Using supplemental fluid viscous dampers to dissipate energy and reduce building response to dynamic inputs is gaining worldwide acceptance. The concept of supplemental dampers added to a structure is that they absorb much of the energy input to the structure from a transient, not by the structure itself, but rather by supplemental damping elements. This paper presents an application of fluid viscous dampers in a high‐rise structure to suppress the anticipated wind‐induced accelerations. The description of the damping system, the design criteria and cost data are discussed. The viscous damper system proves to be a very cost‐effective method to reduce wind motions. Copyright © 2003 John Wiley & Sons, Ltd.