Journal of Applied Physics · 1968 · 32 citations · 1 references
Natural SciencesGeophysicsPlasma PhysicsRadiation MeasurementRadiation PhysicsHigh-temperature PlasmasPlasma DiagnosticsPlasma SourcesAtmospheric PressureAtmospheric Pressure DependenceGas Pressure EffectsGas RadiationRadiation Source CharacterizationSource Strength EstimationTemperature Dependence
If the temperature dependence of the total radiation source strength and the continuum radiation source strength of a gas are known, the contribution of the line radiation can be determined. The investigation of the line factor L shows that it is independent of pressure over a wide temperature and pressure range. Therefore, to determine the total radiation source strength of a gas at high pressure, one need calculate only the continuum radiation at high pressure and use the measured or calculated line factor of the gas at atmospheric pressure. This method was applied to argon and the total radiation source strength u=F (temperature, pressure), in the range 9000≤T≤15 000°K and 1≤p≤100 atm was determined using the existing values measured at 1 atm.
1
Arc Measurement of High-Temperature Gas Transport Properties
Howard W. Emmons · The Physics of Fluids · 1967 · 127 citations
Engineering, Physics, Heat Transfer +16