Journal of Cardiovascular Electrophysiology · 1995 · 15 citations · 22 references
MedicineBiomedical EngineeringCardiologyBioinstrumentationElectrophysiologyInterventional CardiologyCardiac PacingIntracardiac ElectrophysiologyCapacitanceCapacitorsElectrode CapacitanceElectrophysiologic EffectsImplantable Cardioverter DefibrillatorsMaximum OutputMaximum Power OutputPacing Thresholds
INTRODUCTION: The size of current implantable cardioverter defibrillators (ICD) is still large in comparison to pacemakers and thus not convenient for pectoral implantation. One way to reduce ICD size is to defibrillate with smaller capacitors. A trade-off exists, however, since smaller capacitors may generate a lower maximum energy output. METHODS AND RESULTS: In a prospective randomized cross-over study, the step-down defibrillation threshold (DFT) of an experimental 90-microF biphasic waveform was compared to a standard 125-microF biphasic waveform. The 90-microF capacitor delivered the same energy faster and with a higher peak voltage but provided only a maximum energy output of 20 instead of 34 J. DFTs were determined intraoperatively in 30 patients randomized to receive either an endocardial (n = 15) or an endocardial-subcutaneous array (n = 15) defibrillation lead system. Independent of the lead system used, energy requirements did not differ at DFT for the experimental and the standard waveforms (10.3 +/- 4.1 and 9.5 +/- 4.9 J, respectively), but peak voltages were higher for the experimental waveform than for the standard waveform (411 +/- 80 and 325 +/- 81 V, respectively). For the experimental waveform the DFT w as 10 J or less using an endocardial lead-alone system in 10 (67%) of 15 patients and in 12 (80%) of 15 patients using an endocardial-subcutaneous array lead system. CONCLUSIONS: A shorter duration waveform delivered by smaller capacitors does not increase defibrillation energy requirements and might reduce device size. However, the smaller capacitance reduces the maximum energy output. If a 10-J safety margin between DFT and maximum energy output of the ICD is required, only a subgroup of patients will benefit from 90-microF ICDs with DFTs feasible using current defibrillation lead systems.
22
A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.
Gust H. Bardy, Gary R. Johnson, Jeanne E. Poole et al. · Circulation · 1993 · 211 citations · Full text
Effects of chronic amiodarone therapy on defibrillation threshold
Werner Jung, M Manz, Luciano Pizzulli et al. · The American Journal of Cardiology · 1992 · 138 citations
Medicine, Cardiology, Pharmacology +14