Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2014 · 27 citations · 8 references
Computed TomographyMicrosoft KinectEngineeringRespiratory MotionHuman Pose Estimation3D Pose EstimationWearable TechnologyAnatomical Model3D Body ScanningKinesiologyMotion CaptureCt ScanBiostatisticsKinematicsPrincipal Component AnalysisRadiologyHealth SciencesMachine VisionMedical ImagingMedical Image ComputingComputer VisionPhysical TherapyPatient Respiratory MotionEye TrackingHuman MovementMotion Analysis
Patient respiratory motion is a major problem during external beam radiotherapy of the thoracic and abdominal regions due to the associated organ and target motion. In addition, such motion introduces uncertainty in both radiotherapy planning and delivery and may potentially vary between the planning and delivery sessions. The aim of this work is to examine subject-specific external respiratory motion and its associated drift from an assumed average cycle which is the basis for many respiratory motion compensated applications including radiotherapy treatment planning and delivery. External respiratory motion data were acquired from a group of 20 volunteers using a marker-less 3D depth camera, Kinect for Windows. The anterior surface encompassing thoracic and abdominal regions were subject to principal component analysis (PCA) to investigate dominant variations. The first principal component typically describes more than 70% of the motion data variance in the thoracic and abdominal surfaces. Across all of the subjects used in this study, 58% of subjects demonstrate largely abdominal breathing and 33% exhibited largely thoracic dominated breathing. In most cases there is observable drift in respiratory motion during the 300s capture period, which is visually demonstrated using Kernel Density Estimation. This study demonstrates that for this cohort of apparently healthy volunteers, there is significant respiratory motion drift in most cases, in terms of amplitude and relative displacement between the thoracic and abdominal respiratory components. This has implications for the development of effective motion compensation methodology.
8
The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)
Paul Keall, G Mageras, James M. Balter et al. · Medical Physics · 2006 · 2.2K citations · Full text
A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy
Jamie R. McClelland, Jane M. Blackall, S Tarte et al. · Medical Physics · 2006 · 180 citations
Modeling respiratory motion for reducing motion artifacts in 4D CT images
Yongbin Zhang, Jinzhong Yang, Lifei Zhang et al. · Medical Physics · 2013 · 65 citations