Highly Sensitive Ammonia Sensor with Organic Vertical Nanojunctions for Noninvasive Detection of Hepatic Injury
95
Citations
30
References
2013
Year
We successfully demonstrate the first solid-state sensor to have reliable responses to breath ammonia of rat. For thioacetamide (TAA)-induced hepatopathy rats, we observe that the proposed sensor can detect liver that undergoes acute-moderate hepatopathy with a p-value less than 0.05. The proposed sensor is an organic diode with vertical nanojunctions produced by using low-cost colloidal lithography. Its simple structure and low production cost facilitates the development of point-of-care technology. We also anticipate that the study is a starting point for investigating sophisticated breath-ammonia-related disease models.