IEEE Transactions on Instrumentation and Measurement · 1980 · 13 citations · 0 references
Natural SciencesElectrical EngineeringInstrumentationOpticsSensorsFiber OpticsOptical InstrumentsOptical SensingOptical SensorsRefractive IndexWave ReflectionOptical ReflectancePrismatic InterfacesReflectanceRefractive Index SensingRemote Optical SensingSpecular Reflectance
When parallel-polarized light is reflected at an angle ϕ by the interface between two transparent media with refractive indices n and N, the interface reflectance is switched from 1 to 0 by varying the refractive index ratio N/n from sin ϕ to tan ϕ. This is the basis of a light-reflection liquid-level sensor that uses a prismatic window in the side wall of the vessel whose liquid level is to be monitored. Such a sensor is described and its design procedure is developed. Remote liquid-level telemetering is possible by using fiber optics to lead the light to and from this particular sensor.