Laser-induced thermal-acoustic velocimetry with heterodyne detection

Stefan Schlamp, Eric B. Cummings, Thomas H. Sobota

Optics Letters · 2000 · 37 citations · 9 references

Concepts

Abstract

Laser-induced thermal acoustics (LITA) was used with heterodyne detection to measure simultaneously and in a single laser pulse the sound speed and flow velocity of NO>(2) -seeded air in a low-speed wind tunnel up to Mach number M =0.1 . The uncertainties of the velocity and the sound speed measurements were ~0.2 m/s and 0.5%, respectively. Measurements were obtained through a nonlinear least-squares fit to a general, analytic closed-form solution for heterodyne-detected LITA signals from thermal gratings. Agreement between theory and experiment is exceptionally good.

References

9