2012 · 17 citations · 6 references
EngineeringNuclear EngineeringPhysicsNuclear InstrumentationNuclear PhysicsRadiation DetectionNeutron DetectionNeutron ScatteringParticle DetectorsAngular ResolutionDetector DesignDetector Spatial ResolutionGas Pressure EffectsNeutron Detector SystemsNeutron ReflectometryReflectometryThermo-mechanical Constraints
The main goal in neutron reflectometry instruments is to achieve a high angular resolution and high counting rates. Although <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> He shortage affects scientific research in neutron scattering science due to its wide use in detectors as neutron converter; this is not the main issue for neutron reflectometry application where detector sizes are generally moderate. Indeed <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> He detectors are instead limited in spatial resolution. To reduce the particles traces and thereby increase the spatial resolution those detectors are operated at high quencher gas pressure, resulting in mechanical constraints. A promising alternative, to accomplish these goals, is to exploit solid <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> B-films employed in a proportional gas chamber. The challenge with this technique is to attain a suitable detection efficiency. This can be achieved by operating the <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">10</sup> B conversion layer at grazing angle relative to the incoming neutron direction. The Multi-Blade design is based on this operational principle and it is conceived to be modular in order to be adaptable to different applications. A prototype has been developed at ILL and the results obtained on our monochromatic test beam line are presented here. A significant concern in a modular design is the uniformity of detector response: several effects might contribute to degrade the uniformity and they have to be taken into account in the detector concept: overlap between different substrates, coating uniformity, substrate flatness, parallax errors, etc. A simulation has been developed to address these problems.
6
D17: the new reflectometer at the ILL
R. Cubitt, Giovanna Fragneto · Applied Physics A · 2002 · 221 citations
B4C thin films for neutron detection
Carina Höglund, Jens Birch, K.H. Andersen et al. · Journal of Applied Physics · 2012 · 159 citations · Full text