IEEE Transactions on Information Forensics and Security · 2012 · 351 citations · 68 references
EngineeringBioengineeringBiomedical EngineeringAuthenticationBioinstrumentationBiomedical Signal ProcessingBiometric AuthenticationCardiac Signal ProcessingElectrocardiogram AnalysisElectrocardiographyPattern RecognitionVital Signs RecordingAuthentication AlgorithmsBiometric RecognitionBiometric System Performance EvaluationEcg Feature ExtractionElectrocardiogram Feature ExtractionEqual Error RatePerformance DegradationPhysiological Biometrics
The ECG is an emerging biometric modality with 13 years of research, warranting a systematic review of its methods and findings. This paper reviews the techniques used for ECG-based biometric recognition. The authors categorize ECG biometric methods by features and classifiers, then compare authentication performance on an in-house database across same- and different-session scenarios, incorporating multiple training sessions to mitigate performance loss. Results show that ECG algorithms perform well within the same session but degrade across sessions; only a few methods, including the authors’ own, achieve single-digit EERs (5.5%).
The electrocardiogram (ECG) is an emerging biometric modality that has seen about 13 years of development in peer-reviewed literature, and as such deserves a systematic review and discussion of the associated methods and findings. In this paper, we review most of the techniques that have been applied to the use of the electrocardiogram for biometric recognition. In particular, we categorize the methodologies based on the features and the classification schemes. Finally, a comparative analysis of the authentication performance of a few of the ECG biometric systems is presented, using our inhouse database. The comparative study includes the cases where training and testing data come from the same and different sessions (days). The authentication results show that most of the algorithms that have been proposed for ECG-based biometrics perform well when the training and testing data come from the same session. However, when training and testing data come from different sessions, a performance degradation occurs. Multiple training sessions were incorporated to diminish the loss in performance. That notwithstanding, only a few of the proposed ECG recognition algorithms appear to be able to support performance improvement due to multiple training sessions. Only three of these algorithms produced equal error rates (EERs) in the single digits, including an EER of 5.5% using a method proposed by us.
68
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
The DET curve in assessment of detection task performance
Alvin F. Martín, George R. Doddington, Terri Kamm et al. · 1997 · 1.4K citations
Steven A. Israel, John M. Irvine, A. Cheng et al. · Pattern Recognition · 2004 · 667 citations