Medical Physics · 2014 · 79 citations · 17 references
MedicineOncologyRadiation OncologyDiagnostic ImagingRadiation DosimetryTreatment PlanningExternal Beam RadiotherapyImage-guided RadiotherapyImage-guided TherapyMedical ImagingRadiation Imaging SystemsRadiation TherapyExternal Beam Radiotherapy DosimetryImaging-based DosimetryKilovoltage ImagingMegavoltage ImagingReal-time GuidanceReal-time Image GuidanceX-ray Imaging PhysicsX-ray Imaging Systems
PURPOSE: Kilovoltage intrafraction monitoring (KIM) is a real-time image guidance method that uses widely available radiotherapy technology, i.e., a gantry-mounted x-ray imager. The authors report on the geometric and dosimetric results of the first patient treatment using KIM which occurred on September 16, 2014. METHODS: KIM uses current and prior 2D x-ray images to estimate the 3D target position during cancer radiotherapy treatment delivery. KIM software was written to process kilovoltage (kV) images streamed from a standard C-arm linear accelerator with a gantry-mounted kV x-ray imaging system. A 120° pretreatment kV imaging arc was acquired to build the patient-specific 2D to 3D motion correlation. The kV imager was activated during the megavoltage (MV) treatment, a dual arc VMAT prostate treatment, to estimate the 3D prostate position in real-time. All necessary ethics, legal, and regulatory requirements were met for this clinical study. The quality assurance processes were completed and peer reviewed. RESULTS: During treatment, a prostate position offset of nearly 3 mm in the posterior direction was observed with KIM. This position offset did not trigger a gating event. After the treatment, the prostate motion was independently measured using kV/MV triangulation, resulting in a mean difference of less than 0.6 mm and standard deviation of less than 0.6 mm in each direction. The accuracy of the marker segmentation was visually assessed during and after treatment and found to be performing well. During treatment, there were no interruptions due to performance of the KIM software. CONCLUSIONS: For the first time, KIM has been used for real-time image guidance during cancer radiotherapy. The measured accuracy and precision were both submillimeter for the first treatment fraction. This clinical translational research milestone paves the way for the broad implementation of real-time image guidance to facilitate the detection and correction of geometric and dosimetric errors, and resultant improved clinical outcomes, in cancer radiotherapy.
17
Patrick A. Kupelian, Twyla R. Willoughby, Arul Mahadevan et al. · International Journal of Radiation Oncology*Biology*Physics · 2006 · 488 citations
Image-guided radiosurgery for the spine and pancreas
Martin J. Murphy, John R. Adler, Mohan Bodduluri et al. · Computer Aided Surgery · 2000 · 128 citations
A method of dose reconstruction for moving targets compatible with dynamic treatments
P.R. Poulsen, Mai Lykkegaard Schmidt, Paul Keall et al. · Medical Physics · 2012 · 104 citations · Full text