Factors Influencing Pneumothorax Rate at Lung Biopsy: Are Dwell Time and Angle of Pleural Puncture Contributing Factors?

Jane P. Ko, Jo-Anne O. Shepard, Elizabeth A. Drucker, Suzanne L. Aquino, Amita Sharma, Bradley S. Sabloff, Elkan F. Halpern, Theresa C. McLoud

Radiology · 2001 · 172 citations · 16 references

Concepts

Abstract

PURPOSE: To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle. MATERIALS AND METHODS: In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates. RESULTS: One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05). CONCLUSION: Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.

References

16