Clinical Physiology and Functional Imaging · 2002 · 153 citations · 27 references
Health ProfessionsChild HealthPediatricsPediatric PulmonologyPulmonary Function TestingPulmonologyBronchodilator Response TestingPediatric Pulmonary Function TestingRespiratory AssessmentRespiratory DiseaseRespiratory MedicineRespiratory PhysiologyBronchodilator ResistanceFrequency Dependence Of ResistanceImpulse OscillometryInput ImpedanceRespiratory ImpedanceRespiratory Impedance MeasurementRespiratory Resistance MeasurementRespiratory System Resistance
In order to study the determinants of respiratory system impedance and bronchodilator response in preschool children, a sample (n = 109) of healthy children (age 2.1-7.0 years) attending kindergarten was measured by using the impulse oscillometry. Their selection was based on a standardized questionnaire, negative skin prick test results and clinical examination, and sufficient cooperation. Triple measurements of respiratory resistance (Rrs) and reactance (Xrs) at 5, 10, 15 and 20 Hz, total respiratory impedance (Zrs), the resonance frequency (Fr) and the frequency dependence of resistance (dRrs/df) were performed, to determine individual mean values. Measurements were repeated after inhalation of 300 microg salbutamol (n = 89) or placebo (n = 19). At the baseline, Zrs and Rrs5-20 showed negative, and Xrs5-20, Fr and dRrs/df positive correlations with age, height and weight. However, logarithmic transformed height was the best independent variable for the regression equations of all the oscillometric variables. After inhalation of placebo, none of the oscillometric variables changed significantly. In the salbutamol group, the mean (SD) change in Rrs5 was -0.187 (0.124) kPa l(-1) s(-1) and -19.2 (10.2)%, corresponding to a lower reference limit of -36.9%. Both the within-test and between-test repeatabilities for the measurement of respiratory resistance were acceptable, for Rrs5 the coefficients of variation being 6.2 and 6.1%, respectively. As the overall success rate in our sample was high (89%), the forced oscillation technique seems to be a useful method in assessing respiratory function and bronchial lability in preschool children.
27
Lung function measurement in awake young children
Hans Bisgaard, Bent Klug · European Respiratory Journal · 1995 · 299 citations · Full text
A new method to determine frequency characteristics of the respiratory system
F. J. Lándsér, J. Nagles, Maurits Demedts et al. · Journal of Applied Physiology · 1976 · 252 citations
Life Sciences, Physics, Physiology +17
Standardization of lung function testing in children
Lynn M. Taussig, Victor Chernick, Robert J. Wood et al. · The Journal of Pediatrics · 1980 · 185 citations