A Fast Response Highly Selective Probe for the Detection of Glutathione in Human Blood Plasma

Yixing Guo, Xiao‐Feng Yang, Lovemore Hakuna, Aabha Barve, Jorge O. Escobedo, Mark Lowry, Robert M. Strongin

Sensors · 2012 · 85 citations · 21 references

DOIFull text

Open access

Concepts

Abstract

A fluorescent probe for glutathione (GSH) detection was developed. Our study indicates a possible mechanism which couples a conjugate addition and micelle-catalyzed large membered ring formation/elimination sequence. This method enables excellent selectivity towards GSH over other biological thiols such as cysteine (Cys) and homocysteine (Hcy). The proposed method is precise with a relative standard deviation (R.S.D) lower than 6% (n = 3) and has been successfully applied to determine GSH in human plasma with recoveries between 99.2% and 102.3%.

References

21