IRE Transactions on Nuclear Science · 1961 · 11 citations · 4 references
EngineeringNuclear EngineeringPhysicsNuclear PhysicsRadiation PhysicsSemiconductor DevicesAlpha Particle DetectionCharged Particle DetectionNeutron DetectionRadiation DetectorsRadiation SpectroscopySemiconductor DetectorsNeutron Damage EffectsPulse Height SpectraRadiation Damage EffectsRadiation Damage Effects On DetectorsRadiation Damage In DetectorsSemiconductor Neutron DetectorsSilicon DetectorsSilicon Semiconductor Detectors
Two silicon junction charged-particle detectors were irradiated with fast neutrons distributed in energy from 1/2 to 6 Mev. Reverse current and pulse height spectra of U-234 α particles were observed at several bias voltages as functions of neutron dosage. The reverse current of both detectors increased roughly five fold during exposure to 1.2 x 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">13</sup> fast neutrons per cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> . From the α pulse heights the capacitance (at some fixed bias) of one detector vas found to increase roughly 25% per 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">12</sup> nvt. Approximately 50% of this change was restored by 1000 hours of annealing at room temperature. In the other detector, the α pulse height decreased at a similar rate, but the data was obscured by the development of unusually large pulse rise times.
4
K. G. McKay · Physical Review · 1949 · 68 citations
Silicon p-n Junction Radiation Detectors